Closed
Water Mist Suppression System Replacement
Transport for London · Public undertaking
In brief
Transport for London was looking for suppliers for construction work. Bidding has closed and no award has been published yet.
The estimated value is £2,962,195 excluding VAT.
The contract runs for 31 months, up to 43 months with extensions, starting 1 April 2026.
Built from the notice's own fields. Always check the official notice before you bid.
What the notice says
The Water Mist Suppression and Sprinkler Systems requirement is for the procurement of a principal contractor to remove, replace and commission the Water Mist Suppression and Sprinkler Systems currently installed in 34 locations situated within 22 different London Underground stations. TfL's has identified that the fire suppression and sprinkler systems currently installed in the sites (Cleaner's Stores, Bin Stores, Stores and Retail Tenancies) are either life-expired, non-compliant or not fit for purpose under Article 5 of the Fire Precautions Sub-surface Railway Regulations 2009. It has also been identified that these systems do not have / meet the current applicable standards such as BS…Read the full description
The Water Mist Suppression and Sprinkler Systems requirement is for the procurement of a principal contractor to remove, replace and commission the Water Mist Suppression and Sprinkler Systems currently installed in 34 locations situated within 22 different London Underground stations.
TfL's has identified that the fire suppression and sprinkler systems currently installed in the sites (Cleaner's Stores, Bin Stores, Stores and Retail Tenancies) are either life-expired, non-compliant or not fit for purpose under Article 5 of the Fire Precautions Sub-surface Railway Regulations 2009. It has also been identified that these systems do not have / meet the current applicable standards such as BS EN14279 and BS8489.
The water mist systems have been installed on the TfL infrastructure in the early 1990's following the publication of the Fire Precautions Sub-surface Railway Regulations 1989 (updated 2009). The systems were installed where conventional sprinkler systems were not considered viable due to practical or logistical constraints and designed, installed and maintained in compliance with the American Standard NFPA750.
Due to the increasing number, sizes, type of storage and trading activities within the network, further review of risks and tests for these suppression protection systems were undertaken and evaluated. This confirmed a requirement to replace these systems and design modern, compliant equivalent water mist system to replace the ageing noncompliant systems currently installed in the TfL LU estate.
The modern systems will be tested by TfL to BS EN 14972-1 Annex A with a deluge time of not less than 60 minutes from the appropriate number of cylinders located locally, to provide reliable fire suppression to specific rooms identified.
These new installations will be designed for but not limited to Cleaner's Stores, Bin Stores, Stores and Tenancies. In some cases, wet sprinklers systems extensions will replace the ageing Water Mist systems where they are available and economically viable.
Timeline
- Tender notice · UK4, notice 060765-2025
- Tender notice · UK4, notice 061543-2025
About the buyer
Transport for LondonLast 12 months
Procurements
377Awards
150Suppliers it has used most for construction
- Delcore Fire Engineering Ltd2 contracts
- Siemens Mobility Limited2 contracts
- Alan Dick Communications Limited1 contract
- Amalgamated Construction Ltd1 contract
- Amey Rail Limited1 contract
Similar open tenders
All open construction tenders- £15mestimated
- £100kestimated
- £275kestimated
- £8mestimated
- £160kestimated
From notice 060765-2025 on Find a Tender, first published 30 September 2025, last updated 2 October 2025. We last checked for changes on 28 September 2026.